This version of the sensor has a built-in signal conditioner with a voltage or current output and a supply voltage of 5 / 24 V. The signal conditioner is fully integrated in the sensor body. Dimensions and parameters are identical to the EMS110 model. The output can be directly connected to a PLC or other measuring device with suitable inputs.

Note:
Due to the large number of possible combinations of force range, load direction and sensor output, it is complicated to keep them all in stock. Please inquire by email about the availability and delivery time of your chosen combination.

Supported outputs
TypeSupply voltageDirectionOutput
Voltage5 VDCTension / Compression0.5 .. 4.5 V
24 VDCTension / Compression2 .. 10 V
24 VDCTension and Compression2 .. 6 .. 10 V
Current24 VDCTension / Compression4 .. 20 mA
24 VDCTension and Compression4 .. 12 .. 20 mA
Weight0,07 kg
Dimensions55 × 10 × 55 cm
Load direction

Compression, Tension, Tension and Compression

Rated Capacity (Fn)

200N, 500N, 1KN, 2KN, 5KN, 10KN

Output

0,5 – 2,5 – 4,5 V (5 VDC), 0,5 – 4,5 V (5 VDC), 2 – 10 V (24 VDC), 2 – 6 – 10 V (24 VDC), 4 – 12 – 20 mA (24 VDC), 4 – 20 mA (24 VDC)

Datasheet EMS111 - SK Download.pdf
Datasheet EMS111 - EN Download.pdf
Model EMS110 / EMS111 - 200N Download.stp
Model EMS110 / EMS111 - 500N Download.stp
Model EMS110 / EMS111 - 1kN Download.stp
Model EMS110 / EMS111 - 2kN Download.stp
Model EMS110 / EMS111 - 5kN Download.stp
Model EMS110 / EMS111 - 10kN Download.stp
Rated capacity (F.S.)200 / 500 N1 / 2 / 5 / 10 kN
Overload
- Safe
- Ultimate
- Permanent static load
- Dynamic load

120% F.S.
150% F.S.
75% F.S.
50% F.S.
Max error
- Non-linearity
- Hysteresis
- Creep (30 min)

0.1% F.S.
0.1% F.S.
0.05% F.S.
Temperature effect
- On zero
- On output

0.15% F.S./10°C
0.15% F.S./10°C
Temperature range
- Nominal
- Operating

0°C .. +50°C
-10°C .. +50°C
ProtectionIP54
Body materialAluminiumStainless steel
Cable
- Type / Length

LifYDY 7 x 0.05 / 2m

LifYDY 7 x 0.1 / 2m