Precision "S" beam sensor type. Measurement possible in compression and tension directions.
This version of sensor has built-in signal conditioner with voltage or current output. Dimensions and parameters are identical to EMS110.
Output: | Voltage (5 VDC) * |
| Standard | 0.5 .. 4.5 V |
| With zero offset | 0.5 .. 2.5 .. 4.5 V |
| Voltage (24 VDC) * |
| Standard | 2 .. 10 V |
| With zero offset | 2 .. 6 .. 10 V |
| Current * |
| Standard | 4 .. 20 mA |
| With zero offset | 4 .. 12 .. 20 mA |
* Upon agreement, it is possible to set another output.